Fig. 9: Test results of the proposed sensor in the Mach 4 wind tunnel.

a The output voltage comparison results of the Kulite sensor and test sensor. b Test sensor, Kulite Sensor, and pressure scanning values output comparison. c Measurement errors of the test sensor and Kulite sensor under different angles of attack