Figure 6

Fidelity of the array triggering. (a) Illustration of a pulse sequence of the fidelity measurements. The column voltages are measured before and after row triggering. (b) Triggering fidelity versus column bias current and trigger current with 640 writing sequences for each pixel. The red dotted lines indicate the constraints set by the memory element and SFQ control circuits.