Table 1 General geometry of eye models for 134 right eyes before and 6 months after femto-LASIK.

From: Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery

   

Pre-surgery

Post-surgery

Cornea

Anterior Surface[a],*

Radius (mm)

7.77 ± 0.25

8.56 ± 0.43

Asphericity

 − 0.28 ± 0.11

0.63 ± 0.44

Low-order RMS errors (μm)

0.87 ± 0.27

0.80 ± 0.36

High-order RMS errors (μm)

0.09 ± 0.02

0.15 ± 0.05

Posterior Surface[a],*

Radius (mm)

6.35 ± 0.23

6.38 ± 0.22

Asphericity

 − 0.31 ± 0.12

 − 0.26 ± 0.12

Low-order RMS errors (μm)

0.53 ± 0.09

0.53 ± 0.10

High-order RMS errors (μm)

0.04 ± 0.01

0.05 ± 0.01

Thickness (mm)[a]

0.54 ± 0.03

0.45 ± 0.04

Diameter (mm)[d]

12

12

Anterior chamber depth (mm)[a]

3.39 ± 0.28

3.16 ± 0.27

Pupil size (mm)[e]

2, 4, and 6

Lens

Anterior Surface

Radius (mm)[c]

10.83 ± 0.71

Asphericity[d]

 − 3.13

Posterior Surface

Radius (mm)[c]

 − 7.12 ± 0.45

Asphericity[d]

 − 1.00

Thickness (mm)[b]

3.79 ± 0.42

Diameter (mm)[d]

10

Vitreous body

Length (mm)[b]

17.59 ± 0.89

Diameter (mm)[d]

22

Retina

Radius (mm)[c]

 − 12.61 ± 0.08

Asphericity[c]

0.16 ± 0.04

Diameter (mm)[d]

22

  1. *The magnitudes of anterior and posterior corneal surfaces were fitted as sixth-order Zernike polynomials.
  2. [a]Measured by Pentacam (Oculus Optikgeräte GmbH).
  3. [b]Measured by Lenstar LS900 (Haag-Streit).
  4. [c]Estimated based on Eqs. (3–5)39,41,45.
  5. [d]Estimated based on the Navarro eye model34.
  6. [e]Set values for Zemax simulation.