Table 1 Description of the Tajo bridge sensor system.

From: Enhancing stress measurements accuracy control in the construction of long-span bridges

Sensors

Functionality

Load cells

Stress on the suspension stays (30 units)

Stress in the prestressing units of the stay-cable towers (8 units)

Extensometers

Stress in the reinforcement of semi-arches (32 units)

Stress in the starting reinforcement of the stay-cable piers (8 units)

Temperature probes

Vertical thermal gradient in the semi-arches (16 units)

Thermal gradient in stay-cable piers and towers (8 units)

Clinometers

Deformation of the semi-arches (14 units)

Twisting at the head of stay-cable piers and towers (2 units)

Anemometers

Wind incident in the north half-arch advance segment (1 unit)

Wind incident at the head of the stay-cable towers (2 units)

Accelerometers

Stress on the suspension stays (1 unit)

Acceleration on the suspension stays (1 unit)

Acceleration on the semi-arches (2 units)