Table 1 Construction properties of the double leaf wall cases.

From: Airborne sound insulation performance of lightweight double leaf walls with different stud types

Case No.

Stud properties

Wall properties

Type

Spacing

(mm)

Cavity

Leafâ‘ 

A1

Woodâ‘¡

600

Mineral Fiber: 90 mm

Top: 13 mm

Bottom: 13 mm

A2

Wood

600

Mineral Fiber: 90 mm

Top: 13 mm

Bottom: 2 × 13 mm

B1

C-type Steel

(Thickness: 0.53 mm; Flange width: 31 mm)

600

Mineral Fiber: 90 mm

Top: 13 mm

Bottom: 13 mm

B2

C-type Steel

(Thickness: 0.53 mm; Flange width: 31 mm)

600

Air: 90 mm

Top: 13 mm

Bottom: 13 mm

B3

C-type Steel

(Thickness:1.22 mm; Flange width: 34 mm)

600

Mineral Fiber: 90 mm

Top: 13 mm

Bottom: 13 mm

B4

H-type Steel

(Thickness:0.53 mm; Flange width: 31 mm)

600

Mineral Fiber: 90 mm

Top: 13 mm

Bottom: 13 mm

B5

W-type Steel

(Thickness:0.53 mm; Flange width: 36 mm)

600

Mineral Fiber: 90 mm

Top: 13 mm

Bottom: 13 mm

B6

Z-type Steel

(Thickness:0.53 mm; Flange width: 38 mm)

600

Mineral Fiber: 90 mm

Top: 13 mm

Bottom: 13 mm

C1

Staggered Wood

600

Cavity width: 145 mm;

Mineral Fiber (Partial filling):130 mm

Top: 13 mm

Bottom: 13 mm

C2

Double Wood

600

Cavity width: 205 mm

Mineral Fiber (Partial filling):180 mm

Top: 13 mm

Bottom: 13 mm

C3

Staggered C-type Steel

(Thickness: 0.53 mm; Flange width: 31 mm)

600

Cavity width: 145 mm

Mineral Fiber (Partial filling):130 mm

Top: 13 mm

Bottom: 13 mm

C4

Double C-type Steel

(Thickness: 0.53 mm; Flange width: 31 mm)

600

Cavity width: 205 mm

Mineral Fiber (Partial filling):130 mm

Top: 13 mm

Bottom: 13 mm

C5

Rubber isolation clip with C-type Steel

(Thickness: 0.53 mm; Flange width: 31 mm)

600

Cavity width: 145 mm

Mineral Fiber (Partial filling):130 mm

Top: 13 mm

Bottom: 13 mm

  1. â‘  The material of top and bottom leaves is gypsum board.
  2. ② The wooden stud has a cross-section size of 38 × 90 mm and a linear density of 1.6 kg/m.