Table 5 Energy dependencies considering different required DLI and transmittance values: Summer.
Minimum DLI | \(\tau_{G}\) | STPV Allowed Area (m2) | BESS Capacity (kW) | EAF Without BESS (%) | EAF With BESS (%) |
---|---|---|---|---|---|
30 | 0.671 | 3237 | 330 | 43.43 | 24.17 |
0.597 | 2596 | 260 | 47.81 | 27.12 | |
20 | 0.671 | 3486 | 350 | 41.14 | 21.03 |
0.597 | 3486 | 350 | 41.14 | 21.03 | |
10 | 0.671 | 3486 | 350 | 41.14 | 21.03 |
0.597 | 3486 | 350 | 41.14 | 21.03 |