Table 17 DIF comparison results of OC.

From: Experimental study on dynamic mechanical properties of hybrid fiber reinforced concrete at different temperatures

Temperature /°C

Strain Rate /s⁻1

Experimental DIF

Calculated DIF

Error /%

20

39.01

1.21

1.13

-6.37

59.56

1.32

1.29

-2.29

70.29

1.38

1.35

-2.09

95.89

1.51

1.47

6.89

200

44.47

1.13

1.21

2.03

59.56

1.29

1.32

3.46

76.12

1.36

1.41

2.01

103.24

1.49

1.52

1.11

400

39.48

1.18

1.19

3.91

60.43

1.30

1.35

3.19

73.53

1.39

1.42

2.41

99.62

1.53

1.54

0.39

600

44.28

1.29

1.26

-1.94

65.27

1.36

1.41

3.58

75.00

1.44

1.46

1.40

96.86

1.58

1.55

-1.59

800

46.52

1.34

1.31

-2.05

60.22

1.43

1.41

-1.53

85.91

1.52

1.54

1.30

101.06

1.66

1.60

-3.62