Table 2 Design of experimental platform operating conditions.

From: Study on the influence of forced ventilation on the maximum fire temperature in roadway heading

No.

Fuel tray diameter (cm)

The air volume of the duct (m3/min)

Distance from fire source to end (m)

Distance from the air duct outlet to the end (m)

Mass loss rate (g/s)

Heat release rate (kW)

Maximum temperature (K)

1

12

1.90

0

0.5

0.103

2.95

371.1

2

15

0.128

3.67

380.0

3

18

0.145

4.14

408.2

4

22

0.233

6.67

448.2

5

12

2.85

0.100

2.85

326.4

6

15

0.123

3.51

340.7

7

18

0.144

4.13

367.2

8

22

0.216

6.17

414.8

9

12

3.79

0.100

2.87

318.4

10

15

0.118

3.38

320.3

11

18

0.133

3.81

323.6

12

22

0.250

7.16

362.5

13

12

1.90

3.5

0.124

3.56

452.5

14

15

0.135

3.86

422.4

15

18

0.176

5.03

496.6

16

22

0.320

9.15

570.3

17

12

2.85

0.101

2.90

400.2

18

15

0.118

3.37

389.9

19

18

0.168

4.79

471.7

20

22

0.305

8.73

575.6

21

12

3.79

0.115

3.29

373.0

22

15

0.122

3.48

377.1

23

18

0.139

3.99

434.7

24

22

0.268

7.67

568.8