Correction to: Nature Communications https://doi.org/10.1038/s41467-023-38274-2, published online 01 June 2023
The original version of this Article contained an error in Fig. 2g, in which the legend of curve ‘GPML700 20 wt%’ was incorrectly swapped with ‘GPML700 50 wt%’, and ‘GPML500 20 wt%’ was incorrectly swapped with ‘GPML500 50 wt%’.
The original version of this Article omitted that ‘(3-Aminopropyl)triethoxysilane (APTES)’ was obtained from Sigma-Aldrich. This has now been included in the ‘Materials and chemicals’ subsection of the ‘Methods’ section.
Finally, the original version of the Supplementary Information contained errors or misplaced information in Supplementary Tables 2, 4, 6. These were as follows:
In Supplementary Table 2
-
The “Type”, “Linear Sensing Range (kPa)” and “Linear Sensing Factor (Sp)” of the pressure sensor reported in previous Supplementary Reference [18], Zhou H, et al. Capacitive pressure sensors containing reliefs on solution-processable hydrogel electrodes. ACS Applied Materials & Interfaces 13, 1441-1451 (2021), have been incorrectly given as “EDL: mold-based”, “7.4”, and “56.98”, respectively. The correct values are “Conventional: mold-based”, “0.86”, and “6.622”. The line, which was previously in the 3rd row, has been moved to the 11th row and is now Supplementary Reference [26].
-
The “Structure Fabrication Method” of the pressure sensor reported in Supplementary Reference [29], Yang J, et al. Flexible, Tunable, and Ultrasensitive Capacitive Pressure Sensor with Microconformal Graphene Electrodes. Acs Applied Materials & Interfaces 11, 14997-15006 (2019), has been incorrectly given as “Photolithography Silicon wafer”. The correct value is “UV lithography copper foil”.
-
The “Linear Sensing Factor (Sp)” of the pressure sensor reported in Supplementary Reference [32], Qiu J, et al. Rapid-response, low detection limit, and high-sensitivity capacitive flexible tactile sensor based on three-dimensional porous dielectric layer for wearable electronic skin. ACS applied materials & interfaces 11, 40716-40725 (2019), has been incorrectly given as “18.6”. The correct value is “0.0186”.
-
The pressure sensor reported in previous Supplementary Reference [35], Zhang Y, et al. Flexible and Highly Sensitive Pressure Sensors with Surface Discrete Microdomes Made from Self‐Assembled Polymer Microspheres Array. Macromol Chem Phys 221, 2000073 (2020), was incorrectly included in this table. The reported sensor in this work is piezoresistive instead of capacitive. Therefore, this reference has been removed.
In Supplementary Table 4, the 6th row was incorrectly referenced with Supplementary Reference [3]. The correct reference for this row is Supplementary Reference [2], Ji B, et al. Gradient Architecture-Enabled Capacitive Tactile Sensor with High Sensitivity and Ultrabroad Linearity Range. Small 17, e2103312 (2021).
In Supplementary Table 6, the 16th row “Type”, “Sensing Range (kPa)”, and “Sensitivity (kPa-1)” were incorrectly given as “EDL”, “0-7.4”, and “7.7”, respectively. The correct values are “parallel plate”, “0-0.86/0.86-4.90/4.90-7.4”, and “7.7/3.95/1.26”, respectively.
The Supplementary References have been updated to reflect the change of previous Supplementary Reference [18] to Supplementary Reference [26], and removal of previous Supplementary Reference [35].
These have been corrected in both the PDF and HTML versions of the Article. The HTML has also been updated to include a corrected version of the Supplementary Information.
Author information
Authors and Affiliations
Corresponding authors
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Yang, R., Dutta, A., Li, B. et al. Author Correction: Iontronic pressure sensor with high sensitivity over ultra-broad linear range enabled by laser-induced gradient micro-pyramids. Nat Commun 14, 3913 (2023). https://doi.org/10.1038/s41467-023-39675-z
Published:
DOI: https://doi.org/10.1038/s41467-023-39675-z