Introduction

The incidence of in-stent restenosis (ISR) is currently rising by 1–2% per year1,2. Extensive studies of ISR treatment strategies have recommended the drug-coated balloon (DCB) as a Class I A treatment option3. However, adverse events continue to affect prognosis after DCB angioplasty, and effective methods for predicting these events are lacking, highlighting a significant issue.

The quantitative flow ratio (QFR), an innovative computational physiology tool based on three-dimensional anatomical reconstruction and hemodynamic simulation, has demonstrated strong correlation with the invasive wire flow reserve fraction (FFR), improving the diagnostic accuracy of functional stenosis identification through coronary angiography4. In contrast, optical coherence tomography (OCT) offers micron-scale resolution and exceptional lumen imaging capabilities, delivering unique insights into quantitative measurements and qualitative assessments5,6. However, the prognostic implications of the severity of physiological lesions assessed by QFR and neointimal characteristics evaluated by OCT remain unclear. This study aimed to explore the relationship between vessel-level QFR after DCB treatment for ISR and neointimal characteristics evaluated by OCT, along with their association with clinical outcomes.

Methods

Study design, population and study endpoints

This study is a single-center, retrospective, observational cohort study. Between January 2018 and March 2024, ISR is defined as a diameter narrowing of over 50% in the proximal or distal segments of the stent, as determined by angiography2. The exclusion criteria for this study included: poor angiographic image quality preventing QFR measurements, poor OCT image quality, lost OCT images and loss to follow-up. Ultimately, 204 diseased vessels from 204 patients with in-stent restenosis were included in the analysis (Supplemental Fig. 1). Baseline characteristics, QFR measurements before and after DCB angioplasty, OCT imaging prior to and following DCB angioplasty, and clinical follow-up data were analyzed. This study adhered to the ethical guidelines of the 1964 Declaration of Helsinki, received approval from the Ethics Committee of the Affiliated Hospital of Zunyi Medical University, and obtained written informed consent from all participants.

Clinical follow-up was conducted through outpatient visits, telephone contact, or structured follow-up. The primary outcome of the study was a target vessel failure (TVF), defined as a composite endpoint of cardiovascular death, target vessel myocardial infarction and target vessel revascularization according to the Academic Research Consortium-2 (ARC-2) consensus7. Further details regarding study endpoint definitions are provided in Supplemental Appendix 1.

Clinical baseline data, angiographic characteristics and percutaneous coronary nterventions (PCI) procedures

Clinical baseline data were collected from the hospital’s electronic medical record system. This data consists of two main parts: (1) Demographic characteristics of the patients, including gender, age, blood pressure, body mass index, diabetes mellitus, smoking history, bleeding risk, hypertriglyceridemia, history of hypercholesterolemia, and peripheral artery disease. In addition, the patient’s medication use after discharge was recorded. (2) Laboratory analysis included left ventricular ejection fraction and related hematological indicators, including white blood cell count, platelet count, triglycerides, total cholesterol, and markers of myocardial infarction. Details regarding angiographic and PCI procedures analysis are provided in Supplemental Appendix 1.

Off-line QFR computation

Calculating the QFR required uploading two angiographic images with angles of ≥ 25° to the AngioPlus software (Pulse Medical Imaging Technology, Shanghai, China) via a local network. Offline QFR calculations were performed using a previously described algorithm that included automatic depiction of the lumen contour by a thoroughly validated method. Manual corrections were allowed for cases where the angiographic image quality remained suboptimal after standard operating procedures (Fig. 1). In this study, a frame counting method was used to derive contrast flow rates from coronary angiograms for QFR calculation. QFR analysis was performed by well-trained technicians8.

Fig. 1
figure 1

QFR measurement before and after drug coated balloon angioplasty. (A) before drug coated balloon angioplasty; (B) after drug coated balloon angioplasty; QFR quantitative flow ratio.

OCT image acquisition and analysis

All patients underwent OCT before and after DCB angioplasty. The procedure involved an intracoronary nitrate injection, followed by image acquisition using an OCT catheter (Dragonfly Duo, St. Jude Medical) and a frequency-___domain OCT system (ILUMIEN OPTIS Intravessel-level Imaging System; St. Jude Medical, Inc., St. Paul, MN, USA). After delivering the OCT catheter along the guide wire to the distal part of the ISR lesion, it is advisable to advance beyond the stent segment and inject a contrast agent at a rate of 3–5 ml/s to replace the blood in the target vessel, facilitating a clear, blood-free environment for optimal imaging. The retraction and rotation rates were set to 18 mm/s and 100 frames/s, respectively. The total length of the OCT pullback is approximately 75 mm. To ensure optimal quality of the collected OCT images, the procedure was performed by an experienced interventional cardiologist. To ensure the accuracy of the OCT image analysis, two experienced clinicians, blinded to the baseline clinical and angiographic lesion characteristics, were selected for independent analysis. In cases of disagreement, a third independent clinician was consulted to reach a consensus9. For a detailed analysis of the quantitative and qualitative features of OCT, please refer to Supplemental Appendix 1, and the neointimal chaaracteristics of OCT are shown in Fig. 2.

Fig. 2
figure 2

Typical optical coherence tomography images of in-stent restenosis. (A) Homogeneous, (B) heterogeneous, (C) Layered, (D) in-stent neoatherosclerosis (ISNA), (E) thin-cap fibro-atheroma (TCFA), (F) calcification (arrows), (G) neointimal rupture (arrow), (H) macrophage infiltrates (arrow).

Statistical analyses

To accurately assess the characteristics of the collected patient data, we classified the data into categorical and numerical variables. Categorical variables were presented as frequencies and percentages, and comparisons were made using the chi-square test or Fisher’s exact test, when applicable. Continuous numerical variables were represented using different methods based on their distribution: normal distribution as mean ± standard deviation, and skewed distribution as median and interquartile range (IQR). Continuous numerical variables were compared between groups according to their distribution using the Student’s t-test or Mann-Whitney U test. Additionally, receiver operating characteristic (ROC) curves were constructed to calculate the area under the curve and determine the optimal cut-off value for post-procedural QFR, assessing its predictive value for TVF after drug balloon angioplasty. The time to clinical outcome for each neointima and post-procedural QFR was assessed using Kaplan-Meier survival curves, and event-free survival curves were compared with a log-rank test. Independent factors associated with TVF were identified through Cox regression analysis. Logistic regression was conducted to identify independent factors associated with low vessel-level QFR (below the optimal cut-off) following post-DCB angioplasty. Finally, to evaluate the additive value of pre-DCB angioplasty OCT findings and post-DCB angioplasty vessel-level QFR in identifying patients with subsequent TVF, we compared the improvement in the discriminatory and reclassification ability of models that included these factors against a model using only baseline characteristics. Data analysis for this study was conducted using SPSS software (version 29.0; IBM Corp, Armonk, NY, USA) and R version 4.2.3 (R Foundation for Statistical Computing, Vienna, Austria), employing a two-sided significance test with a threshold of P < 0.05.

Results

During a median follow-up of 756 days (IQR: 443.25, 1134.50), a total of 204 patients with ISR underwent OCT-guided DCB angioplasty. A total of 27 patients experienced TVF during the follow-up period. The specific distribution of TVF included: cardiovascular death (3 patients), target vessel myocardial infarction (8 patients) and target vessel revascularization (16 patients). Patients were classified into the TVF group (n = 27) and the non-TVF group (n = 177).

Comparisons between the TVF and non-TVF groups

Comparison of the data between the two groups at baseline revealed that the incidence of peripheral arterial disease was significantly higher in the TVF group than in the non-TVF group (5 [18.52%] vs. 7 [3.95%]; P = 0.011), and the remaining baseline characteristics were not significantly different between the two groups (Table 1).

Table 1 Baseline clinical and laboratory characteristics.

In the comparison of angiographic characteristics, the rate of proximal segment lesions in the TVF group was significantly lower than that in the non-TVF group (4 [14.81%] vs. 74 [36.27%]; P = 0.013). After the DCB angioplasty, minimum lumen diameter in the TVF group (1.82 [IQR: 1.72, 2.10] vs. 2.04 [IQR: 1.81, 2.32]; P = 0.040), rate of diameter stenosis (28.90 [IQR: 21.15, 32.45] vs. 24.20 [IQR: 19.2, 27.80]; P = 0.017), area rate of stenosis (48.80 [IQR: 37.55, 55.50] vs. 42.30 [IQR: 34.60, 46.80]; P = 0.013) were all significantly lower than those in the non-TVF group. The post-procedural vessel-level QFR was compared between the two groups, the TVF group was significantly lower than the non-TVF group (0.89 [IQR: 0.87, 0.93] vs. 0.93 [IQR: 0.91, 0.96]; P < 0.001). And the vessel-level QFR improvement, also significantly lower in the TVF group than in the non-TVF group (0.10 [IQR: 0.07, 0.23] vs. 0.18 [IQR: 0.10, 0.38]; P = 0.007) (Table 2).

Table 2 Baseline angiographic, and procedural characteristics.

Table 3 summarizes the quantitative and qualitative results of DCB before and after angioplasty in ISR patients. In terms of quantitative characteristics, the proximal reference lumen diameter before DCB angioplasty in the TVF group was lower than that in the non-TVF group (2.85 [IQR: 2.70–3.11] vs. 3.13 [IQR: 2.86–3.33]; P = 0.009). Quantitative analysis of post-DCB angioplasty showed minimum lumen diameter in the TVF group (2.26 [IQR: 1.84–2.42] vs. 2.32 [IQR: 2.03, 2.59]; P = 0.034), Minimum lumen area (4.03 [IQR: 3.21, 5.04] vs. 4.65 [IQR: 3.78, 5.63]; P = 0.040), Maximum neointimal thickness (0.54 [IQR: 0.42, 0.72] vs. 0.38 [IQR: 0.31, 0.49]; P < 0.001), Improvement in maximal neointimal thickness (0.55 [IQR: 0.38, 0.70] vs. 0.70 [IQR: 0.52, 0.89]; P = 0.004) were all significantly lower than those in the non-TVF group. According to the analysis of qualitative characteristics of in-stent restenosis lesions, the incidence of heterogeneous neointima (13 [48.15%] vs. 32 [18.08%]; P < 0.001) was significantly higher compared with the non-TVF group (Supplemental Fig. 2). In addition, the incidence of thin-cap fibroatheroma (6 [22.22%] vs. 11 [6.21%]; P = 0.015), neointimal rupture (7 [25.93%] vs. 13 [7.34%]; P = 0.007) were significantly higher than those in the non-TVF group.

Table 3 Optical coherence tomography characteristics.

Factors associated with TVF

The results of the univariable and multivariable Cox regression analyses for TVF are presented in Table 4. Variables with P < 0.1 in the univariable analysis were included in the multivariable Cox regression analysis. The multivariable model indicated that monocyte count, proximal lesional segment, post-procedural vessel-level QFR, and heterogeneous neointima were independently associated with TVF.

Table 4 Cox regression analyses for factors associated with TVF after DCB in patients with ISR.

Among the factors independently associated with TVF, post-procedural vessel-level QFR and heterogeneous neointima are the most critical. Receiver operating characteristic curve analysis revealed that the cutoff value of vessel-level QFR for identifying patients with subsequent TVF was 0.895 (sensitivity: 52%; specificity: 88%; area under the curve: 0.738; 95% confidence interval: 0.629–0.847; p < 0.0001; Supplemental Fig. 3). The incidence of TVF was 6.51 times higher in vessels with low vessel-level QFR (≤ 0.895) compared to those with high vessel-level QFR (>  0.895) (95%CI [2.21–19.91]; log-rank P < 0.0001; Supplemental Fig. 4). The cumulative TVF rate analysis showed that the incidence of TVF in heterogeneous neointima was significantly higher than in the other three types of neointima (log-rank P = 0.0024; Supplemental Fig. 5A). These three types were classified as non-heterogeneous neointima. The incidence of TVF in heterogeneous neointima was 3.80 times higher than in non-heterogeneous neointima (95%CI [1.47–9.83]; log-rank P = 0.0015; Supplemental Fig. 5B). The TVF rate was highest in vessels with both features, followed by those with one feature and those without either feature (Fig. 3A). The TVF rate in vessels with both features was 10.69 times higher than in all other vessels (95% CI [2.05–55.79]; log-rank P < 0.0001) (Fig. 3B).

Fig. 3
figure 3

Kaplan–Meier curves of TVF according to low vessel-level QFR combined with the Presence of heterogeneous neointimal pattern in ISR (A,B). P values were calculated using the log-rank test. TVF target vessel failure, QFR quantitative flow ratio, HR hazard ratio, CI confidence interval.

Factors associated with low vessel-level QFR (≤ 0.895)

Multivariable logistic regression analysis revealed that post-procedural maximum neointimal thickness (OR: 0.016, 95% CI [0.003–0.84]; P < 0.001), improvement in the maximal neointimal thickness (OR: 0.003, 95% CI [0.00–0.06]; P < 0.001) and heterogeneous neointima (OR: 3.60, 95% CI [1.03–12.60]; P = 0.045) were independently associated with low vessel-level QFR (≤ 0.895) (Supplemental Table 1).

Incremental value of vessel-level QFR in identifying patients with subsequent TVF

Figure 4 presents the C-index, net reclassification index, and relative integrated discrimination improvement values for the three models. In comparison to model 1 (monocyte count and proximal lesional segment), model 2 (model 1 plus pre-procedural OCT findings) demonstrated significantly greater discriminatory ability (C-index: 0.714 vs. 0.624; P = 0.048) and reclassification ability (net reclassification index: 0.387; P = 0.036; relative integrated discrimination improvement: 0.103; P = 0.008) for identifying patients with subsequent TVF. Compared to model 2, model 3 (model 2 plus pre-procedural vessel-level QFR) exhibited an even greater discriminatory ability (C-index: 807 vs. 0.714; P = 0.025) and incremental reclassification ability (net reclassification index: 0.588; P = 0.003; relative integrated discrimination improvement: 0.085; P = 0.048).

Fig. 4
figure 4

Discriminatory ability of predictive models for TVF. TVF target vessel failure, OCT optical coherence tomography, QFR quantitative flow ratio, IDI integrated discrimination improvement, NRI net reclassification index.

Discussion

The main findings of this study are as follows: (1) Post-procedural vessel-level QFR and heterogeneous neointima observed via OCT were independent predictors of TVF after DCB angioplasty in patients with ISR. (2) Vessel-level QFR was significantly lower in the TVF group compared to the non-TVF group following DCB angioplasty in patients with ISR. (3) The optimal cut-off value for predicting QFR in TVF is 0.895; additionally, post-procedural maximum neointimal thickness, improvement in the maximal neointimal thickness and heterogeneous neointima were independently associated with low vessel-level QFR (≤ 0.895). (4) The incidence of TVF in ISR patients with low vessel-level QFR and heterogeneous neointima after DCB angioplasty is 10.69 times higher than that in all other vessels. (5) Vessel-level QFR post-DCB angioplasty in patients with ISR provides additional predictive value beyond morphological OCT outcomes for identifying patients at risk for subsequent TVF.

DCB angioplasty is one of the most effective therapeutic strategies for ISR and exemplifies the concept of intervention without stent placement. The mechanism involves using a balloon coated with an antiproliferative drug, which is inflated at the lesion site under specific pressure. This process allows for rapid and uniform transfer of the drug through the lipophilic matrix into the vessel wall, eliminating the need for a permanent implant10. Consequently, the duration of dual antiplatelet therapy is shortened, and the risk of chronic inflammation in the vessel wall is reduced, thereby minimizing the risks of bleeding and revascularization. However, adverse clinical events following DCB angioplasty cannot be overlooked, highlighting the need for appropriate predictive indicators to optimize DCB strategies.

Currently, FFR is the gold standard for determining the need for PCI in patients with coronary artery disease. Previous studies have demonstrated an inverse relationship between post-PCI FFR and future adverse cardiac events. The accepted FFR cut-off for identifying a hemodynamic-related lesion is 0.83. However, the disadvantages of FFR, including its invasive nature and the requirement for pharmacologically induced congestion, contribute to higher costs and result in its underutilization in clinical practice. To address these limitations, QFR was developed to facilitate the calculation of functional parameters more simply and rapidly11. Studies have shown a strong correlation and consistency between QFR and FFR, using FFR as the reference standard12,13. The recently published FAVOR III Europe study indicates that the QFR-guided strategy is inferior to the FFR-guided strategy. However, the correlation and consistency between the two strategies are evident14. These indicate that QFR has significant potential for prognostic assessment, making it crucial to measure QFR values after PCI. A study by Biscaglia et al.15 showed that low QFR values after PCI are independent predictors of adverse events, establishing an optimal cut-off of 0.89 for QFR after PCI. Similarly, research by Ki et al.16 and others demonstrated that lesions with low QFR (< 0.90) are associated with a significantly higher risk of adverse events. Since none of these studies focused on ISR lesions, Liontou et al.17 examined the diagnostic performance of QFR in ISR lesions, using FFR as a reference standard, and found that QFR exhibited high diagnostic performance similar to that of primary lesions. The application of post-procedural physiological assessment was subsequently extended to DCB angioplasty in ISR lesions, with clinical outcomes analyzed yielding consistent results18,19. Our study also reconfirmed these findings, with optimal cut-off values aligning with previous research. Unlike FFR, QFR can be computed using only quantitative lumen information from angiographic images to derive virtual FFR. Therefore, QFR values for ISR lesions after DCB angioplasty are straightforward, efficient, and feasible for predicting clinical adverse events.

OCT is a well-established method for imaging intracoronary structures. Unlike conventional angiography, which provides only basic information about the shape of the vessel lumen without insight into the inner wall, OCT addresses this limitation by offering a comprehensive view of the diseased vessel’s inner wall. It provides detailed tomographic or cross-sectional images of the coronary arteries, including data on the lumen, vessel wall, plaque burden, and the composition and distribution of plaque. This advancement has significantly improved the prognosis for patients undergoing PCI20,21. This method has been utilized to characterize the vessel-level responses following PCI, thereby enhancing our understanding of the development of ISR. Recently, the neointima in ISR lesions identified via OCT has been primarily categorized into homogeneous, heterogeneous, layered neointima, and neoatherosclerosis22,23. Previous research has demonstrated a significant correlation between the chosen treatment approach and neointima patterns, highlighting the superiority of drug-eluting stents (DES) over DCB in cases of heterogeneous neointima24,25. This study further confirmed the poorer prognosis associated with DCB for treating heterogeneous neointima. Previous studies have shown that neointimal abnormalities, such as fibrin deposition or intimal hyperplasia, are commonly observed in heterogeneous neointima26,27. These abnormal inflammatory reactions contribute to adverse clinical outcomes and may underlie the poor prognosis of DCB treatment in such cases.

Recently, incorporating physiological indicators derived from hemodynamics alongside the morphological characteristics observed by OCT for combined prediction has shown to significantly enhance the predictive ability for clinical outcomes16,28. Furthermore, our research strongly supports the applicability of this combined predictor in cases of ISR lesions treated with DCB. To validate the practicality of this finding, further prospective studies with larger sample sizes are recommended.

Study limitations

This study is a retrospective analysis conducted at a single center, which inherently includes limitations associated with its design. First, we excluded patients with poor-quality angiography and OCT images, leading to unavoidable selection bias. Second, the primary outcome of interest, TVF is a composite outcome, and the factors associated with it may differ across various clinical outcomes. Due to the relatively small sample size, we are unable to evaluate each clinical outcome separately and cannot ascertain any differences between them. Third, the study is a post-hoc analysis, and the QFR computation was performed offline, which may affect the accuracy of the QFR values. However, previous studies have demonstrated good consistency between offline and online measurements. Finally, the results of this study should be regarded as exploratory; further prospective studies are needed to determine whether physiological methods based on QFR and morphological methods based on OCT can improve clinical outcomes for patients receiving DCB treatment for ISR.

Conclusions

This study demonstrated that vessel-level QFR and heterogeneous neointima were independent factors associated with TVF in ISR patients after DCB angioplasty. Incorporating QFR measurements alongside OCT findings enhances the ability to discriminate patients at risk for subsequent TVF after DCB angioplasty for ISR.