Introduction

High Energy Density (HED) science has traditionally made ample use of X-ray radiography and imaging to investigate a variety of phenomena, such as the implosions of inertial confinement fusion (ICF) capsules1,2,3,4,5,6,7, X-pinch plasmas8,9,10,11 and the general hydrodynamics of evolution of HED targets12,13. Since the creation of these conditions involves the destruction of the targets in so-called single shot experiments, bright X-ray pulses are needed to obtain quantitative data. Historically, X-ray sources generated by the interaction of high power laser with backlighter targets have been employed, with typical spatial and temporal resolution on the order of tens of micrometers and hundreds of picoseconds or more12,14. Phase Contrast Imaging techniques with backlighters have thus been performed to study the dynamics of mm-scale targets15,16,17,18,19,20,21,22,23, while synchrotrons have reached sub-micron resolutions usually on static samples24,25.

The start of operation of LCLS26 in 2009 opened new possibilities for X-ray imaging in HED science. The coherent properties of the beam allow for imaging with sub-micron spatial resolution, while the short, bright pulses allow temporal resolution of tens of femtoseconds. These combined properties allow for single-shot X-ray imaging techniques to emerge as a leading technique to further our understanding of complex HED phenomena. At LCLS, the Matter in Extreme Conditions endstation27 is specifically tailored to field experiments in HED science. To foster this field of research, the different imaging techniques and instruments have been developed, and are available to its user community.

Fig. 1
figure 1

Overview of the MXI system at MEC in Direct Imaging geometry with the indirect X-ray detector placed about 4 m from TCC behind a fly tube. TCC is Target Chamber Center, the interaction point between the LCLS and the optical lasers.

In this paper, we describe the use and performances of the MEC X-ray Imager (MXI) and the different diagnostic imaging techniques that make use of it, and present preliminary proof of principle experiments to showcase its potential for HED science.

Instrument overview

The MXI instrument has two main components: an in-vacuum X-ray lens stack holder and an in-air optical microscope, as detailed in Fig. 1.

The in-vacuum component is designed for use in the MEC target chamber (technical details on the endstation can be found in Ref.27). It uses compound refractive Beryllium lenses (Be CRL) to focus the X-ray beam to sub-micron spot sizes. The capabilities of such lens stacks have been described extensively in the literature28,29,30,31, and have been used for this purpose at MEC32,33,34. A stack of lenses is placed on alignment stages that positions the lenses in the beam. Up to three stacks of lenses can be placed on the instrument simultaneously, to allow usage of different photon energies and/or focal lengths during an experiment without venting the MEC vacuum chamber. The front stack can accommodate up to 100 lenses, necessary for the higher photon energies. The lens stacks are mounted on a hexapod, allowing for precise alignment with six degrees of freedom: the translations are aligned with the LCLS orthogonal coordinate system and rotation around each of these axis. The hexapod is attached to a linear translation stage with 500 mm travel range to change the distance between the lens stack and the object plane along the LCLS X-ray beam.

Two thin pins are precisely located with respect to the Be CRL stacks on the lens platform and are far from each other along the FEL direction to maximize alignment accuracy. They are initially used for the pre-alignment in air with the reference optical laser collinear with the FEL, and later, in vacuum conditions using the FEL itself via their shadowgraphy on the detector. These pins are critical to allow for a fast while precise alignment, typically achieved in less than 30 min.

Since stacks of Be lenses are known to have aberrations, which can limit their use in imaging and phase contrast application, a phase plate that corrects these aberrations34 can be placed 10 mm in front of the lens set. The phase plate is aligned in the horizontal and vertical direction with two small linear stages, which can also completely retract the corrector. The MXI lens sets can be placed either upstream of the sample (see “Phase contrast imaging geometry” section) for phase contrast imaging or downstream (see “Direct imaging geometry” section) for direct imaging of a sample.

In typical HED experiments, samples are driven by the MEC short or long pulse laser orthogonally to the imaging direction (e.g., a shock is imaged traveling through a sample). To this end a sample holder allowing such geometry is available (see Fig. 2).

Fig. 2
figure 2

(a) 3D model of the target holder with an orthogonal configuration between the long pulse drive laser (in green) and the X-rays (in red). (b) Zoom in of a single target an a pillar suitable for use with the MEC VISAR diagnostic27 (VISAR beam in yellow).

The samples are aligned to TCC with better than 20 \(\upmu\)m accuracy using two long-distance telescopes (see27 for details), which view the sample at orthogonal directions. The MXI can be used to further improve the alignment accuracy down to better than 1 \(\upmu\)m in the plane perpendicular to the FEL. The samples are mounted on a pillar that is screwed to the sample holder. The pillars are designed to accommodate for line of sight of additional scientific diagnostics (e.g. for use in shock experiment to allow for VISAR35 measurements on thin samples).

The image is recorded on the in-air component of the MXI, an X-ray camera that is placed behind the MEC chamber. The camera can be placed between 1.3 and 4.3 m behind the sample plane. For the large propagation distance, a fly tube is inserted and terminated by a 125 \(\upmu\)m thick kapton window to maintain low scattering and absorption transport conditions for the X-ray beam. In general, the farthest distance is preferred to have the largest magnification, although some application may benefit from the shorter distance (i.e., ptychography36). For most experiments, we have used an indirect X-ray imaging Optique Peter microscope37, consisting of three options of Ce:GAGG scintillators and three options of high-numerical aperture infinity-corrected optical microscope objectives (\(\times\) 2, \(\times\) 4 and \(\times\) 10 magnification) to further choose between high-magnification or large field-of-view. This assembly is coupled to an Andor Zyla 5.5 sCMOS optical camera, which has a pixel size of 6.5 \(\upmu\)m. Direct imaging cameras (e.g., ePix or Jungfrau) can be used instead, however the resolution is limited by the pixel size (100 \(\upmu\)m for ePix10k, 50 \(\upmu\)m for ePix100 and 75 \(\upmu\)m for Jungfrau). In addition, multiframe X-ray cameras developed by hCMOS38 with pixel size of 25 \(\upmu\)m39,40,41 and capable of capturing multiple image frames spaced as little as 2 ns apart, can also be used, in conjunction with the LCLS multi-bunch operation mode42,43. An advantage of direct detection compared to scintillator based detection is that these cameras are orders of magnitude more sensitive, and therefore can be used with thicker, higher Z, more absorbent samples.

Phase contrast imaging geometry

The imaging geometry first deployed at MEC44 used a diverging beam at target and optic-free propagation from target to detector plane. A schematic of the setup can be seen in Fig. 3.

Fig. 3
figure 3

Sketch of the MXI setup in phase contrast imaging (PCI) geometry.

The MXI, with a lens set of focal length f, is placed in the MEC vacuum chamber and focuses the LCLS beam to approximately 100 nm. A certain distance, x, behind the focus, a sample is placed in the divergent beam. The X-ray beam propagates to a detector at a distance L behind the sample, leading to a geometric magnification of the sample of \(\frac{L}{x}\). Due to the long propagation distance of the X-ray, phase difference induced by the sample can readily be seen in the image (e.g., clear fringes appear at sharp phase boundaries). Iterative algorithms can be used to retrieve the phase, and if this is successful, the full complex transmission function (i.e., absorption and phase shift) can be calculated. Experiment in this geometries have been fielded at MEC, yielding scientific results on shockwave propagation in diamond44 and the kinetics of phase transformations in silicon45. The setup can be easily combined with X-ray diffraction. Moving the lenses of the MXI closer to the target reduced the field of view of the image, and therefore the area where X-rays hit the target. In this way, diffraction from an area of only a few microns in size can be obtained, and different crystallographic phases in the sample can be identified45. A typical image of a laser-generated shock wave traveling through a sample can be seen in Fig. 4 and more examples have been published in e.g.27,32,44.

Fig. 4
figure 4

The MEC long pulse laser impinges on a plastic ablator coated on a Si target. An elastic shock front, followed by a plastic deformation front indicative of material compression travels from top to bottom. Ablator ejecta coming out of the vacuum-ablator interface are also observed. This raw data, background subtracted only, was taken 20 ns after 8 J of a 10 ns long optical laser pulse hit the ablator. For this image, the X-ray free electron laser delivered 2.5 mJ at the photon energy of 8.2 keV with the SASE bandwidth.

Direct imaging geometry

While the PCI geometry described above has great potential when a full phase retrieval can be performed, it proves to be challenging for HED samples. Without such a phase retrieval, the resolution can be severely limited, and an alternative setup that directly images a sample on the detector has been developed and used at MEC. A sketch of the setup is shown in Fig. 5.

Fig. 5
figure 5

MXI in direct imaging geometry.

In this geometry the Be lenses are placed behind the sample such that the distance to the sample, O, and the distance to the camera, I, matches the well known thin lens formula \(\frac{1}{O} + \frac{1}{I} = \frac{1}{f}\), with f the focal length of the Be lenses. Such a setup allows for imaging intensity contrast of the sample with sub-micron resolution, even when phase reconstruction is not possible.

Fig. 6
figure 6

Background subtracted image of a Siemens star resolution target at 9.5 keV in a false color scale. (a) Full field of view of 110 µm \(\times\) 93 µm. (b) Zoom of the center. The smallest features near the center of the picture have a spacing of 200 nm, resulting in an effective pixel size of about 0.045 nm/px.

The MXI instrument was tested in the direct imaging geometry at 8.2 keV, 9.5 keV and 18 keV photon energy. For 8.2 keV and 9.5 keV, a set of 25 Beryllium lenses with a curvature of 50 \(\upmu\)m were used. At 8.2 keV (9.5 keV), the set has a focal length of 204 mm (264 mm) and was placed 214 mm (281 mm) downstream of the target, leading to an image at the detector, placed 4.3 m behind the lenses, with a magnification of approximately \(\times\) 20 (\(\times\) 15). The position of the lenses was tuned to get the best imaging resolution, using resolution targets. Images of the resolution target are shown in Fig. 6. Where the line widths are separated by 200 nm, we measure a contrast better than 30%, which means that these features are resolve according to the Rayleigh criterion.

At photon energies as high as 18 keV, the setup and alignment is more sensitive since many more Be lenses are needed. In addition, the shortest focal length that can be used is generally larger, leading to a smaller magnification. Nevertheless, the higher photon energy allows using either thicker targets, or targets containing higher Z-elements, while maintaining enough transmission to collect high-quality images. We demonstrated its use with a lens stack of 98 lenses of 50 \(\upmu\)m radius of curvature at their apex, leading to a focal length of 266 mm and a magnification of \(\times\) 15. Measurement on resolution targets showed a resolution similar to 8.2 keV and 9.5 keV.

Examples of the use of the MXI in direct imaging geometry are detailed below. In Fig. 7 a shockwave in a silicon sample, driven by the MEC short pulse laser is depicted.

Fig. 7
figure 7

White-Field corrected image of a shock wave propagating through a silicon sample. The MEC short pulse laser, with pulse length of 45 fs and energy of 1 J was focused down to a spot of 7 \(\upmu\)m diameter on the edge of a Si wafer, 100 \(\upmu\)m thick in the X-ray direction. The image is taken 2 ns after the laser strikes the target. We can clearly observe the propagation of the near-spherical expanding shock wave originating from the laser/surface interaction, as well as compressed (darker) material just behind the shock front. The target is set between about 70 and 150 \(\upmu\)m on the vertical axis, while the rest is vacuum.

This geometry is compatible with both the long pulse and the short pulse laser systems available at MEC, as well as a suite of X-ray and optical diagnostics (e.g. X-ray Diffraction, VISAR, X-ray spectroscopy, optical polarimetry) making it an ideal technique to obtain a complete picture of the dynamics happening in HED samples.

The imaging setup can also be used to measure the spot size of the standard beryllium focusing lenses that are in the MEC beamline. These lenses sit approximately 4.2 m upstream of the center of the MEC target chamber (see27 for details), and therefore a stack with focal length between 3.9 and 4.4 m is generally used for standard MEC experiment, with a best focus around 1.2 \(\upmu\)m. Wavefront measurement have in the past been performed of such lens stack, showing significant spherical aberrations, generating ring-patterns around the focus46. The MXI direct imaging geometry can be used to image the intensity profile of the X-ray beam on the sample. In Fig. 8, we show the intensity profile around the focus of our beamline lenses as imaged by the MXI instrument. The airy-like ring pattern can be clearly seen. This type of measurement is of importance for all optical pump—X-ray probe experiments where X-rays are usually being used out of focus in the hope of illuminating a more uniform area. Our high-resolution imager shows, through the measurement of the X-ray caustic profile, that it might not be the case.

Fig. 8
figure 8

Intensity profile of the focus of the MEC beamline lenses in steps of 40 mm. A set of 7 Be lenses with curvature of 300 \(\upmu\)m at their apex, leading to a focal length of 4.22 m was chosen. 800 \(\upmu\)m pinhole were placed in before and after the lens set to restrict the X-ray to the useful aperture of the lenses.

Table 1 summarizes the working envelop of the MXI and its expected performances in direct imaging mode. The device can provide high resolution X-ray imaging over the full X-ray energy range available at MEC, albeit at varying resolution and magnification which are a function of the incoming photon energy. The total magnification is a combination of the X-ray magnification provided by the Be CRL in vacuum (this mainly constrains the diffraction limited performances), and the optical magnification provided by the objective used in the Optique Peter assembly (this allows for oversampling of the X-ray images).

Table 1 Summary of the specifications of the MXI.

Talbot imaging

A special capability of using the MXI in direct imaging mode is its compatibility with Talbot interferometry47,48. Considering the MXI capabilities and the applications of interest like Warm Dense Matter (WDM) and High Energy Density Plasmas (HEDP) studies, different phase retrieval methods can be employed (see the references on Talbot imaging herein). In direct imaging configuration, the data obtained with the MXI present artifacts introduced by the density inhomogeneities of each transmissive Be lens from the stack. Some of these structures can be treated by a simple white field correction (i.e., dividing the image of the sample by the white field of image when no sample is present) or by more sophisticated analysis method such as Principal Component Analysis41,49. This is the analysis that is performed in the images in Figs. 4, 6 and 7. However, a large enough number of white field images (the image of the X-rays on the detector when no sample is present) needs to be accumulated in order to improve the correction with a single shot. This is necessary because the Be CRL are chromatic and the FEL bandwidth jitters, which means that a small change of the incoming central photon energy changes the focal length of the stack, effectively changing the magnification onto the detector. A division of a single shot by a white field can thus be challenging. Alternatively, grating-scanning methods50,51, can provide improved phase-retrieval accuracy considering X-ray optics and thus enabling wavefront reconstruction independent of FEL probing beam illumination profile52,53. These abilities further motivate the use of the MXI in combination with Talbot interferometry methods to mitigate these lens artifacts and chromaticity.

Talbot interferometry has been widely used at FELs to determine the wavefront of the X-ray beam, and its focal properties in a single shot46,54,55,56. The method uses a two dimensional phase diffraction grating placed in the beam. At a specific distance behind the grating self-image57,58 of the grating is reproduced. Analysis of the distortions, typically using Fourier methods59,60 yields the differential phase in two orthogonal dimensions. These differential phases can be integrated to yield the full wavefront of the beam, and back-propagating to the focus yields the focal properties. It has been an important technique to quantify the focus in experiments where X-ray foci of order 100 nm were required. While Talbot X-ray imaging diagnostics have been developed for HEDP applications using laser-based X-ray illumination61,62,63, we leverage FEL beams to improve spatial resolution, optimizing the diagnostic sensitivity by combining this Talbot phase measurement technique with the direct imaging. The setup, which can be seen in Fig. 9, is essentially the same as the direct imaging setup, with the addition of a Talbot grating.

Fig. 9
figure 9

Talbot Phase Imaging at MEC. The MXI is placed in a direct imaging geometry, where the Be lens stack images the sample onto an X-ray camera. A two dimensional checkerboard \(\pi\)-phase grating is placed at the distance of the first Talbot order before the camera.

A checkerboard \(\pi\)-phase grating with a pitch of 22.5 \(\upmu\)m was placed at a distance of 48 cm from the scintillator, which corresponds to the first Talbot order self-image.

The raw image of the shock propagating through 200 \(\upmu\)m of silicon with this setup is shown in Fig. 10. For these results, we used a set of 25 Beryllium lenses with a radius of curvature of 50 \(\upmu\)m and a photon energy of 8.2 keV.

Both the elastic precursor, as well as the phase transformation to denser shocked state of Si, can be seen in the raw image. Overlaid on this image is the grid pattern introduced by the Talbot grating (a zoomed region is shown in the inset) that is used to measure the phase. The two dimensional fringe pattern is analyzed by standard Fourier methods59. There are many ways46,64,65,66,67,68 to integrate the differential phase, and get the phase \(\phi (x,y)\). Since Talbot imaging is a shearing interferometry method, the resolution will depend on the amount of shear (a combination of the pitch of the Talbot grating and the order used), on the magnification introduced by the Beryllium lenses (the limit of which is highly dependent on photon energy and physical constrains) as well as on the reconstruction method (e.g. the bandwidth of the filter used in the Fourier filtering59). Ultimately, it will have a theoretical limit given by the pitch of the grating due to the Nyquist–Shannon sampling theorem.

The sensitivity to phase changes will also depend on these parameters. For example, there is no phase sensitivity at all to phase changes with spatial periods equal to the amount of shear (as defined in Eq. (1)), due to the zero in the transfer function of the shear operator. Therefore, the amount of shear (i.e. Talbot pitch and order) will have to be carefully chosen depending on the features in the samples that experimentalists want to reveal, and with which resolution and sensitivity they want to examine them. The optimal reconstruction method will depend on these choices, and on the amount of noise in the data images. A full treatment and review of the various options is beyond the scope of this paper. In our demonstration experiment, we used the first Talbot order and therefore the shear is small, which gives good phase sensitivity for the high spatial frequencies that sharp shock waves induce, as well as good spatial resolution (at the expensive of sensitivity to lower spatial frequencies). For such a small shear, we can use fast and simple method69,70 and approximate the shear operator as:

$$\begin{aligned} S_x(x,y)&=\phi (x,y)-\phi (x-s,y)=s\frac{\partial \phi }{\partial x}, \end{aligned}$$
(1)
$$\begin{aligned} S_y(x,y)&=\phi (x,y)-\phi (x,y-s)=s\frac{\partial \phi }{\partial y}. \end{aligned}$$
(2)

We then use the Fourier relation:

$$\begin{aligned} {\mathscr {F}}\left( \frac{\partial \phi }{\partial x}\right) =ik_x {\mathscr {F}}(\phi ). \end{aligned}$$
(3)

From this follows:

$$\begin{aligned} \phi ={\mathscr {F}}^{-1}\left( \frac{\mathscr {F} (S_x+iS_y)}{ik_x- k_y}\right) , \end{aligned}$$
(4)

which can be efficiently implemented using a fast Fourier transform and its inverse.

We used this method on a shock compressed silicon sample driven by the MEC long pulse laser, as detailed in Fig. 10.

Fig. 10
figure 10

(a) Raw camera image of a shock in a 200 \(\upmu\)m silicon sample, at 8.2 keV. (b) Reconstructed differential phase \(S_y\) of Eq. (2). (c) Recovered Transmission of sample. (d) Integrated phase of the sample, \(\phi (x,y)\) is Eqs. (1) and (2).

First, an image was taken of the white field illumination (i.e., the beam without a sample in place) to use as a reference. Then, an image of the shocked the sample was taken. Figure 10a shows that raw camera image of the shock, while the reconstructed transmission of the sample is shown in Fig. 10c. The structure that the set of Be lenses introduces is highly visible in both images. Figure 10b shows the differential phase in the y direction, i.e. \(S_y(x,y)\) in Eq. (2). In Fig. 10d we show the actual phase, \(\phi (x,y)\) introduced by the sample; the structure in the intensity introduced by the lenses disappears, as it is not present in the phase. The phase change behind the elastic wave can clearly be seen, as well as the larger shift after the phase change.

We should note however, that the shock fronts that we image are, at these pressures, expected to be only a few (tens) of atomic layers thick. Since we cannot resolve this, we only measure a jump in the phase at the shock front. Any additional phase jump of an integer multiple of \(2\,\pi\) can therefore not be distinguished (e.g. similar to VISAR71 measurements where only one interferometry arm is used). Additional diagnostics (e.g. VISAR) or prior knowledge of the shock will have to be used to resolve this ambiguity. In the data shown in Fig. 10, with photon energy of 8.2 keV the resolution of the phase measurement is approximately 1.2 \(\upmu\)m. We have also successfully tested the method at 17 keV, however with less resolution due the smaller magnification. Since our current scintillator based camera requires a minimum sample transmission of approximately 5%, higher photon energies can be helpfull to investigate thicker targets, or higher Z materials. The ultimate limit of resolution that we can likely reach with the MXI at MEC can be much lower than shown in this demonstration experiment: a magnification of up to \(\times\) 40 at photon energies below 10 keV can be achieved, and combined with a 4 \(\upmu\)m Talbot pitch, a resolution of 8 \(\upmu\)m in the phase measurement at the detector or \(\tfrac{8\,\upmu m}{40}=200\) nm lies within the realms of the possible.

Concluding remarks

In conclusion, we have developed an X-ray imaging diagnostic at MEC that is available to the user community. It can be used in combination with the MEC long pulse laser to, for example, image shock waves and phase transformation in materials over large field of view, and with the MEC short pulse laser system, to image its interaction with dense plasmas at high resolution. The diagnostic has a 200 nm spatial resolution, taking 50 fs (the pulse duration of the FEL) snapshot of excited HED samples, and can operate using photon energies ranging from 5 to 24 keV. In combination with the direct imaging geometry, a Talbot Imaging setup can be used to measure both intensity and phase changes introduced by a target with sub-micron resolution.